UNITSPECTSample Moisture Audit

This is a sample moisture audit with fictional property, unit and inspection data. It shows the format UnitSpect clients receive for each unit inspected.

UNITSPECT
Moisture Integrity AuditReport ID US-2026-MT-0805
Issued Oct 21, 2026

Unit 805 · Maple Tower

Bathroom & Moisture Integrity Audit · Stack 05

PropertyMaple Tower (sample)
Unit805 · Stack 05
ProgramMoisture Audit
Inspection dateOct 21, 2026 · 1:10–1:28 p.m.
Entry noticePosted Oct 19 · window 1–2 p.m.
Wet areas inspectedKitchen, bathroom, laundry

Summary

Moisture risk Elevated

An active leak under the kitchen sink and ceiling staining near the living room window need repair before damage spreads. Tub caulking can be restored rather than replaced. Unit 905 above should be checked as the likely source of the ceiling staining.

2Repair now
2Restore
14Good

Restore vs. replace scope

IDWet area & findingSpread riskRecommendationPhotos
KIT-07Active leak at sink P-trapWater pooling; cabinet base stained, not yet swollenHighRepair Replace trap washer; dry and seal cabinet base2
LIV-03Ceiling staining at window cornerStaining spreading into wall; likely source aboveHighRepair Check unit 905 wet areas and window seal; then repair and repaint3
BTH-03Tub caulking separationGap along back wall, approx. 60 cm; tile soundMediumRestore Remove and recaulk; no tile replacement needed2
BTH-05Grout cracking at tub edgeHairline cracks, two joints; no hollow tilesLowRestore Regrout two joints and seal1
UnitSpect · Moisture Audit · US-2026-MT-0805Page 1 of 3
UNITSPECT
Unit 805 · Maple TowerReport ID US-2026-MT-0805
Oct 21, 2026

Photo evidence

Water dripping from a sink P-trap onto a stained cabinet base1
KIT-07 · Leak at sink P-trapRepair
Photo 1 of 2 · Oct 21, 2026 · 1:14 p.m.Active drip at trap connection; staining on cabinet base.
Brown water staining spreading across a ceiling corner above a window2
LIV-03 · Ceiling stainingRepair
Photo 1 of 3 · Oct 21, 2026 · 1:22 p.m.Staining at ceiling corner above window, extending down the wall.

Wet area checklist

Kitchen 1 repair

  • P-trap & connectionsRepair
  • Supply lines & shut-offsGood
  • Dishwasher connectionGood
  • Sink rim & backsplash sealGood

Bathroom 2 restore

  • Tub & shower caulkingRestore
  • Tile & groutRestore
  • Toilet base & supplyGood
  • Exhaust fanGood
UnitSpect · Moisture Audit · US-2026-MT-0805Page 2 of 3
UNITSPECT
Unit 805 · Maple TowerReport ID US-2026-MT-0805
Oct 21, 2026

Stack follow-up

UnitReasonRecommended action
905Directly above LIV-03 ceiling stainingInspect bathroom, kitchen and window seal before repairing unit 805 ceiling
705Directly below KIT-07 active leakCheck kitchen ceiling for staining

Sign-off

UnitSpect Inspector #04
Signed Oct 21, 2026 · 1:28 p.m.
Property manager review
Date reviewed: ______________

This report records visible conditions at the time of inspection. It is not a structural, engineering or code compliance certification. Concealed conditions behind walls, ceilings and finishes are outside the scope of a visual inspection.